What to do when more outputs are needed?
Published:2014-06-26 16:36:58

Any distribution amplifier has a finite number of outputs. If more outputs are needed, a second DA may be connected to the first using the loop option, which is built-in in higher quality distributors. The connection procedure is as follows: Connect the video/audio source to the input of the first DA. Connect the inputs of the second DA to the LOOP connector of the first DA. Connect the inputs of the third DA to the LOOP connector of the second DA, and so on. Turn all the termination switches near the input connectors to the Hi-Z position in all machines but the last. On the last DA, toggle the termination switch to the 75 Ohms position. Connect all video/audio acceptors to the output sockets of the DAs. Do not cascade the machines, using one active output as input to the next DA, as quality may degrade.